Vertical Fiber Enclosure Dome type GJS03-M1AX-96C (cum fibra cartallum), GJS03S-96C, FOSC 400 A4

Description:

Productum hoc adhibetur ad connectendum funem distributionis et funem ineuntes, late applicatum in communicationis retis systematis, CATV cable TV et sic de aliis.Ipsum plasticum scientifice formatum adoptat et ab iniectione fingatur, cum anti-canus, anti-morsio, flamma retardat, IMPERVIUS, anti-vibratio et effectus anti-molesti.Efficaciter impedire possunt fibrae opticae ab influxu environment velit.
Turpe dome-ut-silii;craticula usque ad 4 scutellas, cardo pro accessu cuiuslibet spli, sine turbatione aliorum ferculorum;Ieiunium et certa sigillatio perficiendi, facilis sarcina multiplex est.Fulmineo munimento fabrica, applicari potest supra caput, murum ascendentem vel immediate sepeliendum.


  • MALITIA Price:US $0.5 - 9,999 / Piece
  • Min.Order Quantitas:100 Piece/Picies
  • Facultates copia:(X) Piece / Mass per mense
  • Product Detail

    Product Tags

    Specifications

    Model GJS03-M1AX- 96-***
    Size: Cum fibulationibus maximus dia externa. 422.3*219.2 mm Rudimentum Dome, Base: modified PP, clamp:Nylon +GFTray: ABSMetal parts:Imaculata ferro
    Portus numerus introitus: I ovalis portum per IV port Praesent rhoncus diam. Oval portavailable pro 2 pcs, 10~ 29mm cablesRound portuum. Quisque available pro 1pc 6-24mm cable
    Maximilianus.Ipsumque numerus 4 scutra Basi modum signandi Calor-horreat
    Facultatem Tray 24F Applications Aeria, directe se- pulta, Murus/polus adscendens
    Maximilianus.splice facultatem Agricola 96F IP gradus 68

    Ordo Ducatus

    GJS03-M1AX-96D_40

    Exterior Diagram

    GJS03-M1AX-96D_52

    Technical Parameter

    1. Operationis Temperaturae: -40 gradus centigradae ~ LXV gradus centigradus
    2. Pressura atmosphaerica: 62~ 106Kpa
    3. Axial tensio: >1000N/1min
    4. Resistentia Platten: 2000N/100 mm (1min)
    5. Insulation resistentia: >2* 104MΩ
    6. Voltage Fort: 15KV(DC)/1min, nullus arcus supra vel naufragii
    7. Temperature redivivus: sub -40℃~+65℃, cum 60(+5)Kpa pressionis interioris, in 10cyclis;Interna pressio minus quam 5 Kpa minuetur cum clausura ad temperiem normalem convertetur.
    8. Durabilitatem XXV annorum

    GJS03-M1AX-96D_35

    Principalis Components

    Nomen Qty Picture Nomen Qty Picture
    Dome 1pc GJS03-M1AX-96D_42 Tray Max.4 pcsoptional GJS03-M1AX-96D_26RQP-06-24c media splice
     GJS03-M1AX-96D_55RQP-08-24c latus splice
    Fibulae 1pc GJS03-M1AX-96D_12 Valvae 1 GJS03-M1AX-96D_27ad libitum
    Base 1pc GJS03-M1AX-96D_35 Mutatio o anulum 1 GJS03-M1AX-96D_08
    Cable confirma membrum laminam attach 1set GJS03-M1AX-96D_23 Velcro habena una X lanula 1 GJS03-M1AX-96D_07
    opticus articulis praesidium tube Maximilianus.96 GJS03-M1AX-96D_16 Humus feed per lug 1 GJS03-M1AX-96D_30
    ad libitum
    Metallum calathum I vexillum oblatum GJS03-M1AX-96D_44 Repono cartallum plasticum 1Orderd ad libitum GJS03-M1AX-96D_33
    Nylon tie & Transparent PE tube 8pcs/peram GJS03-M1AX-96D_19GJS03-M1AX-96D_03
    Quilibet duo fercula cum I pera.
    Murus conscendens rhoncus posuere 1Standard oblatum est GJS03-M1AX-96D_05 GJS03-M1AX-96D_50
    Aeria ascendens rhoncus quam Ut ad libitum GJS03-M1AX-96D_18GJS03-M1AX-96D_53
    Poli conscendens rhoncus posuere Ut ad libitum GJS03-M1AX-96D_20 GJS03-M1AX-96D_32
    Circum Portus accessiones pera 1 sacculum GJS03-M1AX-96D_01 Items Calor-horreat fistula 4 GJS03-M1AX-96D_43
    Abrasive tape 1 GJS03-M1AX-96D_38
    aluminium foil 4 GJS03-M1AX-96D_13
    Oval portum accessiones sacculi 1bag GJS03-M1AX-96D_06 Items Calor-horreat fistula 1 GJS03-M1AX-96D_09
    Abrasive tape 1 GJS03-M1AX-96D_38
    aluminium foil 2 GJS03-M1AX-96D_13
    Purgatio textus 1 GJS03-M1AX-96D_41ad libitum
    Desiccant 1 GJS03-M1AX-96D_10ad libitum
    Clypeus continuum filum 1 GJS03-M1AX-96D_02ad libitum
    AMP Fibulae 1 GJS03-M1AX-96D_25ad libitum
    Germen clip 1 GJS03-M1AX-96D_17

    Installation ductu

    GJS03-M1AX-96D_22

    1. Secare portus opus est ad guide-in cable

    GJS03-M1AX-96D_37

    2. Funem per horrere fistulam calor

    GJS03-M1AX-96D_46

    3. Vagina dilabi et mundare.Seca membrum confirma 5cm longitudinis.Pone eam per cochleas appone et flecte eam figere in cochleam.Tunc obstringere cochleam.

    GJS03-M1AX-96D_04

    4. Solve tubo funem aufer et fibras nudas emunda.Per pellucidum pone fistulam PE.PVC taeniola utens ad extremum PE fistulam et funem involvendum.

    GJS03-M1AX-96D_004

    5. Ventus immoderatus solvens buffers in opportunis cyclis et pone in calatho repositorium.

    GJS03-M1AX-96D_003

    6. Coiling fibrarum opticorum in scutulis splicibus ut supra picturam ab imo lance usque ad summum unum.Coagmenta fusionem et fistulas refugiant et in lance figant.Ipsumque operculum indue.

    GJS03-M1AX-96D_005

    7. Utere Velcro habena ad liganda fercula.

    GJS03-M1AX-96D_005

    8. Usura laesura habena ad asperam superficiem vaginae funeri et portus leviter.

    GJS03-M1AX-96D_006

    9. mundare superficiem fune portuumque

    GJS03-M1AX-96D_009

    10. Movere fistulam aestus ad operiendum portum basim et funem.Attende fistulam in cable fini et in eo velo infige aluminium.Hyacinthus linea movendi ad eundem locum notati.(Osa quae prope lineam caeruleam erit in tubi parte. Ex altera parte e tubi.) Retusum instrumentum utens veli veli arcte adhaeret fune.Cale fistulam recusare sigillum a directione sagittae rubrae lente.(Si 2 funiculos in portu ovali regere, ramum tondet utere ad funes dividendos, ramum off tonde interim calefaciendo ad spatium signandum.)

    GJS03-M1AX-96D_007

    11. Portus rotundas aestus eodem gradu cum ovalibus portibus se- quitur

    GJS03-M1AX-96D_0011

    12. clausurae fibulae.

    GJS03-M1AX-96D_0012

    13. Elige idoneam rhoncus posuere ad varias institutionis ambitus.









  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis